We use Crystal ID by BBL (I think) and they are easier to use than API.
Also work for non-fermenters. I didn't even know enterotubes were
around anymore. We use GNI Vitek cards for most of our identifications,
with the Crystal ID as a backup.
Judy Dilworth, M.T. (ASCP)
Microbiology
DES O'CONNOR wrote:
>> I used this system perhaps 15 years ago. Didn't like it one bit......
> Do your self a favor Yersinia use API, MIcrobact some similar system.